BZC 220/380V 10A Explosion-proof switch series Explosion-proof operation column Explosion-proof control box

Explore our factory-made explosion-proof switch series, operation column, and control box. Designed for 220/380V with 10A capacity, ensuring safety in hazardous environments.

Request a Quote
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box
  • BZC  220/380V  10A  Explosion-proof switch series   Explosion-proof operation column  Explosion-proof control box

PRODUCTS DETAILS

Explosion-proof operation column (box) (hereinafter referred to as operation column), explosion-proof operation column is also called explosion-proof control box, explosion-proof button box, and dozens of buttons can be installed according to user needs. It can be used in the explosive gas environment of IIB and IIC in the factory and the dangerous places with explosive dust of T1-T6 group in Zone 21-22, for the control of electrical equipment in the circuit of AC 50Hz, voltage AC220V/380V/DC24V. Explosion proof mark ExdeIICT6Gb/ExtD A21 IP65 T80°C. The shell of the operation column (box) is made of high-quality steel plate and stainless steel plate with a thickness of 1.5mm-3mm. Incoming and outgoing cables are sealed with cable glands. The panel can be installed with explosion-proof lamps, buttons, ammeters, voltmeters, buttons with lights, potentiometers and other body explosion-proof components. Explosion-proof components should have their own explosion-proof certificate. Terminal blocks can be installed inside. The inlet specification is conventionally inch pipe thread, and metric thread or NPT thread can also be processed according to user requirements, please specify when ordering.1.Execution standard: GB3836.1-2000, GB3836.2-2000, GB3836.3-2000 2. Explosion-proof mark: Exde ⅡBT6/ Exed Ⅱ CT6 3. Protection class: IIB products are IP54, IIC products are IP65 4. Anti-corrosion Grade: WF1 5. Use category: AC-3, AC-4 6. Rated voltage: 220V/380V (please specify if there are special requirements) 7. Rated current: 10A 8. Inlet thread: G1″ (if any Please specify special requirements) 9. Cable outer diameter: φ12mm~φ19mm 10. Indicator voltage code: a: AC/DC 12-36V b: AC, DC48-100V c: DC220V d: AC220.380V 11. Indicator color Code: R: red G: green Y: yellow w: white 12. Button contact type code: I: one normally open and one normally closed II: two normally open III: two normally closed 13. Ammeter accuracy and specification: 1.5 Class, 0.1A, 0.5A, 1A, 1.5A, 3A, 5A, 7.5A, 10A Note: Connect the external current transformer with secondary current 5A, this ammeter is overload meter, the overload current is 5 times , can also provide 3 times or 2 times overload ammeter according to requirements, please explain if there are special requirements. 14. Voltmeter accuracy and specifications: 1.5 class, 30V, 50V, 75V, 100V, 120V, 150V, 200V , 250V, 300V, 400V, 450V, 600V, 450V-450KV Note: It can be connected to an external voltage transformer with a secondary voltage of 100V. Explosion-proof switch seriesExplosion-proof switch series Explosion-proof switch seriesFeatures: 1.Explosion-proof button box is suitable for AC 50Hz, 220/380V, DC voltage to 220V line, remote centralized control of the start and stop of multiple motors. 2. It is composed of increased safety shell, flameproof components (indicator light, ammeter, voltmeter, potentiometer, button, universal switch) and wiring terminals. 3. The shell is made of aluminum alloy casting (high-voltage electrostatic spraying after shot blasting) or glass fiber reinforced unsaturated polyester resin molding. It has excellent properties such as beautiful shell, corrosion resistance, antistatic impact resistance and good thermal stability. 4. The built-in components are directly clamped on the standard guide rails. The protrusions on the components and the grooves on the guide rails ensure that the built-in components are installed in a certain position. The minimum center distance between the components and the components is 42mm. 5, can be steel pipe or cable wiring. 6. There are many variations of this product, which can be made according to the electrical schematic diagram provided by the user. 7. There are more than 30 functions of the universal switch, which can be selected by users as required. 8. It can be equipped with a rain cover according to user requirements. 9. The specially designed sealing structure can effectively improve the product protection level while meeting the explosion-proof performance. 10. Comply with GB3836-2000, IEC60079 standard requirements. Note: Due to the ever-changing arrangement of components in the control box, the arrangement of components with body should be designed and manufactured by our company according to the electrical schematic diagram provided by the user when ordering, jointly study the schematic diagram of the arrangement of components or put forward requirements. Scope of application: 1. Zone 1 and Zone 2 hazardous locations; 2. "Exde Ⅱ BT6" products are suitable for IIA, IIB explosive gas environments; 3. "Exed II CT6" products are suitable for IIA, IIB, IIC explosive gas environments; 4 ."Exed Ⅱ CT6" product is also suitable for combustible dust places; 5. It can be used for long-distance electromagnetic operation in the circuit or for on-off and conversion control of signal and control circuits, and can also be used in the vicinity of the controlled motor. , Indirectly start, stop and reverse operation; the operation column equipped with ammeter can also monitor the motor operation or circuit condition.

Hot Products

CKJ5 Series 380/1140V Vacuum AC Contactor

CKJ5 Series 380/1140V Vacuum AC Contactor

CK(BK/XK/LK)GKL 10-35KV 200-3000A 500-2000Kvar High Voltage Dry Air Core Reactor Series Parallel Reactor Current Limiting Filter Reactor

CK(BK/XK/LK)GKL 10-35KV 200-3000A 500-2000Kvar High Voltage Dry Air Core Reactor Series Parallel Reactor Current Limiting Filter Reactor

FSP 35/66/110/220KV composite windproof  insulator for high voltage transmission line

FSP 35/66/110/220KV composite windproof insulator for high voltage transmission line

DL  16-800mm² 8.4-21mm  Aluminium Connecting Terminal   Cable Lug  Electric power fitting

DL 16-800mm² 8.4-21mm Aluminium Connecting Terminal Cable Lug Electric power fitting

U type 20-38mm  U-Shackle ring  Power link fittings for overhead lines

U type 20-38mm U-Shackle ring Power link fittings for overhead lines

KYN61 40.5KV 1250A 1600A 2000A Armoured Removable High Voltage Switchgear HV Complete Set

KYN61 40.5KV 1250A 1600A 2000A Armoured Removable High Voltage Switchgear HV Complete Set

BHG1 series  200-400A  3-10KV  Mine explosion-proof high-voltage cable junction box

BHG1 series 200-400A 3-10KV Mine explosion-proof high-voltage cable junction box

 W  20-39mm  Socket clevis Power link fitting of Overhead line

W 20-39mm Socket clevis Power link fitting of Overhead line

PAL series   1KV  16-150mm²     Aluminum alloy strain clamp for optical cable(Cable conductor tensioner)

PAL series 1KV 16-150mm² Aluminum alloy strain clamp for optical cable(Cable conductor tensioner)

YDF  0.6/1KV  61-1605A  10-1000mm²  Waterproof flame retardant single-core multi-core prefabricated branch power cable

YDF 0.6/1KV 61-1605A 10-1000mm² Waterproof flame retardant single-core multi-core prefabricated branch power cable

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours