XRNT 6KV 12KV 20KV 24KV 35KV 40.5KV 50KA High voltage current limiting fuses for protection of transformers

Introducing XRNT series high voltage current limiting fuses for transformer protection. As a factory, we offer reliable and durable solutions. Shop now!

Request a Quote
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers
  • XRNT 6KV 12KV 20KV  24KV 35KV 40.5KV  50KA High voltage current limiting fuses for protection of transformers

PRODUCTS DETAILS

It can be used in indoor system of 50HZ and rated voltage of 3.6KV, 7.2KV, 12KV, 24KV, 40.5KV used together with other switch facilities such as loading switches, vacuum contractors, it can protect electric transformers and other electric facilities against overloading or circuit break. it is also a necessary accessory for high-voltage switch.High voltage current limiting fuseHigh breaking capacity: The rated breaking current of the product is 40KA~50KA. Low power loss: ensures a low temperature rise of the product, which is more advantageous when fuses are used in fully enclosed insulation devices. Low arc voltage: During the breaking process, the arc voltage is low, and when used in systems below the rated voltage, the arc voltage will further decrease, which can be used for 12KV or 7 There is no danger of damaging the insulation of the 2KV system. Small characteristic curve error: The error of the time current characteristic curve is less than ± 10%, ensuring the reliability of the product. Standardization of specifications: The rated parameters of the product comply with the International Electrotechnical Commission (IEC) standards R10 and R20 series. There are two types of wiring: (1) Busbar type, with overall dimensions in accordance with British (BS) standards; (2) , plug-in, with external dimensions in accordance with German (DIN) standards; Moreover, they all comply with the International Electrotechnical Commission (IEC) standards. The busbar type can be directly fastened to the busbar with screws, which has the advantages of small installation volume and reliable contact; The plug-in type is easy to replace and can be operated with power. Can be equipped with an impactor: Tungsten wires in parallel with the melt can melt within a few thousandths of a second at the beginning of the arc, igniting the powder device. The firing pin operated by a small amount of gunpowder immediately acts and provides a signal with sufficient energy, or causes other electrical appliances to act, or provides interlocking. The output energy of the fuse impactor that meets the British (BS) standard is (1-3) joules, while the output energy of the fuse impactor that meets the German (DIN) standard is (2-5) joules.

Hot Products

PS/PSN  25-66KV  3-12.5KN  Post type porcelain insulator for outdoor high voltage  Power line

PS/PSN 25-66KV 3-12.5KN Post type porcelain insulator for outdoor high voltage Power line

(ZR)BV 1.5/2.5/4/6mm² 450/750V  Low-voltage flame-retardant single-core copper wire for home improvement engineering

(ZR)BV 1.5/2.5/4/6mm² 450/750V Low-voltage flame-retardant single-core copper wire for home improvement engineering

GCK  380-660V  630-3150A  Low voltage draw out switch cabinet for mining  power distribution cabinet

GCK 380-660V 630-3150A Low voltage draw out switch cabinet for mining power distribution cabinet

JLS-35KV/100V 5-300A 30/50VA 10/20VA Outdoor Oil-immersed Combination Transformer High Voltage Power Metering Box

JLS-35KV/100V 5-300A 30/50VA 10/20VA Outdoor Oil-immersed Combination Transformer High Voltage Power Metering Box

CKSG 10-60Kvar 11-77A Three-phase series filter reactor

CKSG 10-60Kvar 11-77A Three-phase series filter reactor

OQJ/OZJ/OHJ  10/20/35KV  250/630/1250A   Power cable joint   European type rear connected arreste  Cabel accessories

OQJ/OZJ/OHJ 10/20/35KV 250/630/1250A Power cable joint European type rear connected arreste Cabel accessories

SVR 6-35KV 630-20000KVA Outdoor three-phase high voltage line feed automatic voltage regulator

SVR 6-35KV 630-20000KVA Outdoor three-phase high voltage line feed automatic voltage regulator

GTL  10-630mm²  4.5-34mm  Copper-Aluminium connecting tubes cable lugs

GTL 10-630mm² 4.5-34mm Copper-Aluminium connecting tubes cable lugs

GM  250/300/400A  660/1440V  Special explosion-proof isolation reverse switch for coal mine

GM 250/300/400A 660/1440V Special explosion-proof isolation reverse switch for coal mine

FD2 6.3/10/11√3KV 1.7-3.4Mvar outdoor high voltage parallel capacitor special discharge coil

FD2 6.3/10/11√3KV 1.7-3.4Mvar outdoor high voltage parallel capacitor special discharge coil

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours