HRW 12/35KV Outdoor high voltage protection AC drop-out fuse

Buy HRW 12/35KV Outdoor high voltage protection AC drop-out fuse from our factory. Ensure safety with this quality product. Order now for reliable protection.

Request a Quote
  • HRW 12/35KV Outdoor high voltage protection AC drop-out fuse
  • HRW 12/35KV Outdoor high voltage protection AC drop-out fuse
  • HRW 12/35KV Outdoor high voltage protection AC drop-out fuse
  • HRW 12/35KV Outdoor high voltage protection AC drop-out fuse
  • HRW 12/35KV Outdoor high voltage protection AC drop-out fuse
  • HRW 12/35KV Outdoor high voltage protection AC drop-out fuse
  • HRW 12/35KV Outdoor high voltage protection AC drop-out fuse
  • HRW 12/35KV Outdoor high voltage protection AC drop-out fuse
  • HRW 12/35KV Outdoor high voltage protection AC drop-out fuse

PRODUCTS DETAILS

Drop-out fuse cutout and load switching fuse cutouts are outdoor high voltage protection devices. They are connected with the incoming feeder of the distribution transformer or distribution lines. These are primarily used to protect transformers or lines from short circuits and overloads and switching currents. The drop-out fuse unit is composed of insulator supports and a fuse tube, static contacts are fixed on two sides of the insulator support and moving contact is installed on two ends of fuse tube. The interior of the fuse tube is the extinguishing tube. the exterior is made of the phenolic compound paper tube or epoxy glass. Load switching cutout fuse provides stretch auxiliary contacts and arc-extinguish closure for switching on/off loading current. In normal operation, the fuse link is tightened to form tho closed position. In the fault current situation, the fuse link melts and an electrical arc is formed. The arc-extinguishing tube is as occurs. This causes high pressure inside the tube and causes the tube to separate from the contacts. The strength of the contact is relaxed once the fuse elements melt. The cutouts now in the open position, the operator needs to switch the current off. Then with an insulated operating bar, the moving contact can be pulled off. The main contact and auxiliary contact is connected.参数 安装Melt tube structure: Fuse take made of flberglsaa, damp-proof & corrosion-proof. Fuse base: Product base embedded mechanical structure and insulator. Install metal rod mechanism using special binder materials and insulator together , can with stand short-circuit current open the electric power. Moistureproof fuse has not blister, deformation, open ,large capacity, UV,long life, superior electric properties, dielectric strength and excellent mechanical stiffness and consecrated ability. The whole organization to neutral, convenient installation, safe and reliable. 1. The ambient temperature is not higher than +40 C, not lower than-40 C 2. The altitude does not exceed 3000m 3.The maximum wind speed does not exceed 35m/s 4. The earthquake intensity does not exceed 8 degrees1. When working normally, fuse link tightened the fuse tube to be close position. 2. If system occur faults, big fault current melts fuse immediately and take place electric arc, which makesarc extinguishing tube being heated and explode a lot of gases. This will produce high pressure and blow off the arc along with tube. 3. After fuselink melt moving contact has no tightened strength, mechanism is locked and fuse tubedropout. 4. Cutout now is in open position. Operator shall use insulating Link Rod to pull the moving contact.

Hot Products

MGG  50-200mm  Bus-bar  supports fixing clamp Substation fitting

MGG 50-200mm Bus-bar supports fixing clamp Substation fitting

BXK  220/380V  10A    Explosion-proof and anti-corrosion control box  Explosion-proof power distribution device

BXK 220/380V 10A Explosion-proof and anti-corrosion control box Explosion-proof power distribution device

JDZX9-35KV  30/150/300VA Switchgear Electric energy metering cabinet single-phase dry-type voltage transformer

JDZX9-35KV 30/150/300VA Switchgear Electric energy metering cabinet single-phase dry-type voltage transformer

JCD 16-300mm² 1.5-70mm² 150-270A  Electric meter box into the household wire clip

JCD 16-300mm² 1.5-70mm² 150-270A Electric meter box into the household wire clip

MGF  45-250mm  Substation fitting Dead-end caps (Damper type) Electric power fittings

MGF 45-250mm Substation fitting Dead-end caps (Damper type) Electric power fittings

HRW/HRXWO   10-35KV  10A   Outdoor pollution resistant type silicon rubber high voltage current limiting fuse

HRW/HRXWO 10-35KV 10A Outdoor pollution resistant type silicon rubber high voltage current limiting fuse

MY/MYP  0.38/0.66/1.14KV  4-400mm2   Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine

MY/MYP 0.38/0.66/1.14KV 4-400mm2 Mobile explosion-proof flame-retardant rubber sheathed flexible copper cable for coal mine

TBP85-131 6/10KV three-phase combined overvoltage protector overcurrent and thermal shutdown lightning protection

TBP85-131 6/10KV three-phase combined overvoltage protector overcurrent and thermal shutdown lightning protection

JDJJ2 35KV 35000/√3V 0.5/6P outdoor high voltage oil immersed voltage transformer

JDJJ2 35KV 35000/√3V 0.5/6P outdoor high voltage oil immersed voltage transformer

XRNP 6KV 12KV 40.5KV  50KA High voltage current limiting fuses for protection of voltage transformers

XRNP 6KV 12KV 40.5KV 50KA High voltage current limiting fuses for protection of voltage transformers

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours