FZW28-12F 630A 12KV outdoor demarcation high voltage vacuum load switch

Choose our factory for high quality FZW28-12F 630A 12KV outdoor demarcation high voltage vacuum load switch. Experience efficient performance and reliable service.

Request a Quote
  • FZW28-12F 630A 12KV outdoor demarcation high voltage vacuum load switch
  • FZW28-12F 630A 12KV outdoor demarcation high voltage vacuum load switch
  • FZW28-12F 630A 12KV outdoor demarcation high voltage vacuum load switch
  • FZW28-12F 630A 12KV outdoor demarcation high voltage vacuum load switch
  • FZW28-12F 630A 12KV outdoor demarcation high voltage vacuum load switch
  • FZW28-12F 630A 12KV outdoor demarcation high voltage vacuum load switch

PRODUCTS DETAILS

FZW28-12F series outdoor demarcation vacuum load switch is suitable for outdoor three-phase AC power distribution system with rated voltage of 12KV and rated frequency of 50Hz, used for opening and closing load current and closing short-circuit current. FZW28-12F series outdoor demarcation vacuum load switch is suitable for substations, industrial and mining enterprises and automatic distribution networks of urban and rural power grids for protection and control, and places with frequent operations. This product can also be used for the operation control switch for overhead line power distribution system. There are various types, with outstanding advantages such as oil-free, simple structure, reliable performance, and no maintenance. It has been widely used so far. The product is combined with FDR type fault detector or RTU remote control terminal device and other equipment to form a distribution automation system with a simple structure, which can realize automatic location of overhead line faults and automatic isolation of fault sections. In order to update the existing distribution switchgear and make it realize the need for the transformation of distribution equipment characterized by oil-free and automation.参数 外形尺寸及安装Automatically cut single phase earthing fault : when users tributary line cause single phase earthing fault, the boundary switch will open automatically, other distribution line users of the substation and feeding line will be without influence; isolation interphase short circuit fault automatically. When the tributary line cause interphase short-circuit fault, boundary switch will open at once after out-wire protection tripping. After the substation reclose, fault line is isolated passively,other distribution users in feeding line resume power supply rapidly(equal to a transient fault). Quick localization of fault: the tributary line fault cause boundary switch protection action, only the accident user cause power cut and by itself report the fault information, the power company could dispatch worker to life investigation;if the boundary switch match with communication module, it could transmit message to electricity management center. Monitoring users load, boundary switch could configure wired or wireless communication enclosure to monitor data and transmit to electricity management center,make the achievement of real-time data monitoring of users load in long distance. Function of network running, it could be used in network lines,function of measurement,monitor voltage,current,frequency and quantity of electricity of lines,and transmit to management center in long distance.Function of harmonic analyzing to supply reliable basis for pollution administration of electricity net afterwards.Ambient temperature:-10ºC-+40ºC Relative humidity:The average humidity of a day should be no more than 95%. The average humidity of a month should be no more than 90%. Earthquake intensity: not exceed 8 degrees. Saturated vapor pressure the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more Than1.8Kpa; The height above sea level:≤1000 m (Except special requirements) It should be installed in the places without fire, explosion, serious filth, and chemical erosion and violent vibration.

Hot Products

XGN2 3.6KV 7.2KV 12KV 630-2500A Indoor box-type fixed metal enclosed switchgear

XGN2 3.6KV 7.2KV 12KV 630-2500A Indoor box-type fixed metal enclosed switchgear

JLSZW 10KV 5-1000A 10-80KA Outdoor Stainless Steel Combined Transformer Dry Inverted Power Metering Box

JLSZW 10KV 5-1000A 10-80KA Outdoor Stainless Steel Combined Transformer Dry Inverted Power Metering Box

UB/PS/PD/P  series  20-50mm  70-600KN  Overhead Electric Power line link fitting  clevis

UB/PS/PD/P series 20-50mm 70-600KN Overhead Electric Power line link fitting clevis

XGN66 3.6KV 7.2KV 12KV 630A 1250A Fixed box type high voltage switchgear control equipment

XGN66 3.6KV 7.2KV 12KV 630A 1250A Fixed box type high voltage switchgear control equipment

SF(Z)11 series  60KV  6300-63000KVA   Three phase air-cooled on load (non excitation) oil immersed voltage regulating power transformer

SF(Z)11 series 60KV 6300-63000KVA Three phase air-cooled on load (non excitation) oil immersed voltage regulating power transformer

XGU  5-26mm  Jumper suspension clamp Electric power fittings

XGU 5-26mm Jumper suspension clamp Electric power fittings

JXD 35-240mm² 28*50mm wedge-shaped aluminum alloy C-type wire clamp overhead cable clamp

JXD 35-240mm² 28*50mm wedge-shaped aluminum alloy C-type wire clamp overhead cable clamp

RFM 0.375-1.2KV 180-1000kvar Indoor High Voltage Water Cooling Reactive Compensation Electric Heating Capacitor

RFM 0.375-1.2KV 180-1000kvar Indoor High Voltage Water Cooling Reactive Compensation Electric Heating Capacitor

MWL  63-125mm  Outdoor  supports for bar (Vertical setting)  Substation fitting

MWL 63-125mm Outdoor supports for bar (Vertical setting) Substation fitting

YH5WZ 35KV zinc oxide arrester for high voltage power station

YH5WZ 35KV zinc oxide arrester for high voltage power station

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours